When choosing an embedded industrial computer, check its ESD evidence, not just the enclosure. IEC 61000-4-2 Level 4 requires 8 kV contact discharge. Its 2008 test waveform specifies a peak current of about 30 A, rising in roughly 0.8 nanoseconds. That is a sharp pulse. It can upset exposed ports, reset a processor, or corrupt a sensor reading.
Ask for the actual test report. It should identify the tested configuration, discharge points, polarity, and operating state. The IEC standard also defines 15 kV air discharge for Level 4, but that does not replace the 8 kV contact test. During evaluation, watch the console and connected equipment for resets, lost data, or communication faults. A green status light is not enough. Small details matter.
A pass applies to the tested setup, not every installation. Cable length, grounding, and nearby metal can change the discharge path. One uncomfortable detail: a test report may not reflect your cabinet. Compare its mounting and cabling with your own, and retest when the installation differs substantially.
I would also ask whether the computer recovered automatically after exposure. Recovery behavior can matter as much as survival.